MAX48A-32J02FE0650 1124112 Linear encoders: MAX SICK

Category: Linear encoders
Sku: 1124112

Fast 24-hour shipping across Egypt

Delivery within 3-7 working days Worldwide

Money Back Guarantee

Check Here
Country Of Origin: DE HS Code: 90318020 EAN: 4047084501203 MAX48A-32J02FE0650 1124112 Download Datasheet

Not Available On Stock, Deilver in 6 Weeks, Also You Can Order DHL Within 2 Weeks

Description

MAX48A-32J02FE0650 1124112 Linear encoders: MAX SICK Products Motion control sensors Linear encoders > Motion control sensors > Linear encoders > MAX > MAX48A-32J02FE0650 CE|RCM|UKCA

Items supplied Accessories not included with delivery, please order separately.
MTTFD (mean time to dangerous failure) 69 years (EN ISO 13849-1) 1)
Type 48 mm installation housing – IN cylinder mounting
Pressure pipe/End cap 10 mm / Flat
Connection type Male connector, M12 type L (24×24 mm), 5-pin
Direction of connection Axial
Measuring rangeMeasured valuesPositioningPosition (F.S.)0 mm … 650 mm 1)Null zone30 mmDamping zone63 mm Measuring range
Measuring range
Measured values Positioning
Position (F.S.) 0 mm … 650 mm 1)
Null zone 30 mm
Damping zone 63 mm
Operating conditionsFluid temperature–30 °C … +95 °C 2)Air humidity90 % (Condensation not permitted)Operating pressure PN400 barSupply voltage24 V DC (8 … 32 V DC)Switch-on time< 250 msSwitch-on currentTyp. 5.0 A / 50 µsMeasuring frequency (internal)1 msTransmission rate (cycle time)20 ms Operating conditions
Operating conditions
Fluid temperature –30 °C … +95 °C 2)
Air humidity 90 % (Condensation not permitted)
Operating pressure PN 400 bar
Supply voltage 24 V DC (8 … 32 V DC)
Switch-on time < 250 ms
Switch-on current Typ. 5.0 A / 50 µs
Measuring frequency (internal) 1 ms
Transmission rate (cycle time) 20 ms
AccuracyHysteresis± 0,1 mmRepeatabilityTyp. ± 0.2 mmLinearityTyp. ± 0.25 mm (measuring range 50 to 500 mm) 3)Typ. ± 0.04% F.S. (measuring range from 500 to 2,500 mm) Accuracy
Accuracy
Hysteresis ± 0,1 mm
Repeatability Typ. ± 0.2 mm
Linearity Typ. ± 0.25 mm (measuring range 50 to 500 mm) 3)
Temperature driftWarming up phaseTyp. ≤ ± 0.25 mm (2 min)In the operational statusTyp. ± 0.25 mm (measuring range 50 to 500 mm) 3)Typ. ± 0.04% F.S. (measuring range from 500 to 2,500 mm) Temperature drift
Temperature drift
Warming up phase Typ. ≤ ± 0.25 mm (2 min)
In the operational status Typ. ± 0.25 mm (measuring range 50 to 500 mm) 3)
Communication interface SAE J1939
Address settingBaud rate250 kbit/sSource Adress02 Address setting
Address setting
Baud rate 250 kbit/s
Source Adress 02
Network Management Protocol SAE J1939-81
Application Layer SAE J1939-71
PIN assignment 1=n.c.; 2=V DC; 3=GND; 4=CAN_H; 5=CAN_L
Electrical operationSupply voltage24 V DC (8 … 32 V DC)Residual ripple< 1% S-SPower consumption≤ 0.75 WCurrent consumption≤ 30 mABus termination (external)120 Ω Electrical operation
Electrical operation
Residual ripple < 1% S-S
Power consumption ≤ 0.75 W
Current consumption ≤ 30 mA
Bus termination (external) 120 Ω
Overvoltage protection during power-up (60 s) ≤ 36 V at all poles during power-up (60 s)≤ 48 V To GND during power-up (60 s)
Reverse polarity protection ≤ 36 V (at all poles) (ISO 16750-2)
Insulation resistance Riso ≥ 10 MΩ, 60 s (ISO 16750-2)
Dielectric strength 500 V DC, 0 V DC (60 s) to housing (RISO ≥ 1 MΩ) (ISO 16750-2)
Short-circuit protection VS – GND on housing
DimensionsHousing48 mm, 48f7 for IN cylinder mounting – cylinder bore hole 48H8Ø pressure pipe10 mmØ O-ring40.87 mm x 3.53 mmØ support ring42.6 mm x 48 mm x 1.4 mmM12 flangeM12 flange type L: DM 24×24 mm – hole pattern 17 mm (EN 61076-2-101)Wire length100 mm Dimensions
Dimensions
Housing IP67 (EN 60529)
Ø pressure pipe 10 mm
Ø O-ring 40.87 mm x 3.53 mm
Ø support ring 42.6 mm x 48 mm x 1.4 mm
M12 flange Nickel-plated brass with O-ring (NBR)
Wire length 100 mm
MaterialHousingStainless steel 1.4305 (AISI 303)Pressure pipeStainless steel 1.4404, AISI 316LO-ringNBR 70Support ringPTFEM12 male connectorGlass fiber reinforced polyamide, nickel-/gold-plated brass contactsM12 flangeNickel-plated brass with O-ring (NBR)StrandsPVC Material
Material
Pressure pipe Stainless steel 1.4404, AISI 316L
O-ring NBR 70
Support ring PTFE
M12 male connector IP69K (ISO 20653) 3)
Strands PVC
EMCEU Directive 2014/30 / EU CE markingGeneric standardsEN 61000-6-2/61000-6-3Agricultural and forestry machineryEN ISO 14982Transient pulsesISO 7637-2/ISO 16750-2ESD (air and contact discharge)ISO 61000-4-2 / ISO 10605 EMC
EMC EU Directive 2014/30 / EU CE marking
Generic standards EN 61000-6-2/61000-6-3
Agricultural and forestry machinery EN ISO 14982
Transient pulses ISO 7637-2/ISO 16750-2
ESD (air and contact discharge) ISO 61000-4-2 / ISO 10605
VibrationSine20 g (sine) / 55 … 2,000 Hz / 3×24 h (IEC 60068-2-6 Fc)Sine over noise18 g (r.m.s) / 10 … 2,000 Hz / 3×36 h (IEC 60068-2-80 Fi)Broadband noise (resonance peaks removed)20 g (r.m.s) / 10 … 2,000 Hz / 3×48 h (IEC 60068-2-64 Fh) Vibration
Vibration
Sine 20 g (sine) / 55 … 2,000 Hz / 3×24 h (IEC 60068-2-6 Fc)
Sine over noise 18 g (r.m.s) / 10 … 2,000 Hz / 3×36 h (IEC 60068-2-80 Fi)
Broadband noise (resonance peaks removed) 20 g (r.m.s) / 10 … 2,000 Hz / 3×48 h (IEC 60068-2-64 Fh)
Pressure loadOperating pressure PN400 barOverload pressure Pmax = PN x 1.2480 barTest pressure Pstat = PN x 1.5600 bar Pressure load
Pressure load
Overload pressure Pmax = PN x 1.2 480 bar
Test pressure Pstat = PN x 1.5 600 bar
Temperature and air humidityStorage–20 °C … +65 °C 1)Operation (electronics)–40 °C … +105 °C 2)Maximum air humidity90 % (Condensation not permitted) Temperature and air humidity
Temperature and air humidity
Storage –20 °C … +65 °C 1)
Operation (electronics) –40 °C … +105 °C 2)
Maximum air humidity 90 % (Condensation not permitted)
Enclosure ratingHousingIP67 (EN 60529)M12 male connectorIP69K (ISO 20653) 3) Enclosure rating
Enclosure rating
EU declaration of conformity
UK declaration of conformity
ACMA declaration of conformity
Moroccan declaration of conformity
China RoHS
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
ECLASS 5.0 27270705
ECLASS 5.1.4 27270705
ECLASS 6.0 27270705
ECLASS 6.2 27270705
ECLASS 7.0 27270705
ECLASS 8.0 27270705
ECLASS 8.1 27270705
ECLASS 9.0 27270705
ECLASS 10.0 27270705
ECLASS 11.0 27270705
ECLASS 12.0 27274304
ETIM 5.0 EC002544
ETIM 6.0 EC002544
ETIM 7.0 EC002544
ETIM 8.0 EC002544
UNSPSC 16.0901 41111613
header value
Unit weight 0.910 Kilograms
Net unit weight 0.91 Kilograms
Unit volume 10560 Cubic Centimetres (cm³)
Country of origin Germany
EAN 4047084501203
Additional information
Weight 910 g
Reviews (0)
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.

MAX48A-32J02FE0650 1124112 Linear encoders: MAX SICK
Home Shop Cart Account
Select your currency
EGP Egyptian pound