Products Detection sensors Automation light grids > Detection sensors > Automation light grids > SLG-2 > SLG25S-010SAR21D20 CE|IO-Link|cULus|RCM|UKCA
Not Available On Stock, Deilver in 6 Weeks, Also You Can Order DHL Within 2 Weeks
Products Detection sensors Automation light grids > Detection sensors > Automation light grids > SLG-2 > SLG25S-010SAR21D20 CE|IO-Link|cULus|RCM|UKCA
| Included with delivery | 1 × sender
1 × receiver 1 × Quick Start Guide 1 x safety notes |
|---|---|
| Functional principle | Sender/receiver |
| Sensing range Limit values 440 mm … 4,900 mm Parallel beam (recommended) 440 mm … 3,500 mm 5 x cross beam (recommended) 440 mm … 3,500 mm |
Sensing range |
| Sensing range | |
| Limit values | 440 mm … 4,900 mm |
| Parallel beam (recommended) | 440 mm … 3,500 mm |
| 5 x cross beam (recommended) | 440 mm … 3,500 mm |
| Blind zone Distance from 1st Beam to leading edge of housing (connection side) 4.6 mm Distance from last beam to leading edge of housing (top) 19.6 mm 1) |
Blind zone |
| Blind zone | |
| Distance from 1st Beam to leading edge of housing (connection side) | 4.6 mm |
| Distance from last beam to leading edge of housing (top) | 19.6 mm 1) |
| Detection height | 100 mm |
| Beam separation | 25 mm |
| Optical light exit | Slim |
| Detection capability Minimum detectable object (MDO), parallel beam 30 mm 2) Minimum detectable object (MDO), 5 x cross beam ≥ 12.5 mm 2) Minimum object width (MOW), 5 x cross beam 43 % 3) 4) |
Detection capability |
| Detection capability | |
| Minimum detectable object (MDO), parallel beam | 30 mm 2) |
| Minimum detectable object (MDO), 5 x cross beam | ≥ 12.5 mm 2) |
| Minimum object width (MOW), 5 x cross beam | 43 % 3) |
| Factory setting Beam function 5 x cross beam Pin 2 (MF) Teach-in input Pin 4 (OUT) Object detection output = “HIGH” IO-Link (process data) QL/Qint Status, System status, Beam status Teach-in (default) Auto teach-in |
Factory setting |
| Factory setting | |
| Beam function | 5 x cross beam |
| Pin 2 (MF) | Teach-in input |
| Pin 4 (OUT) | Object detection output = “HIGH” |
| IO-Link (process data) | QL/Qint Status, System status, Beam status |
| Teach-in (default) | Auto teach-in |
| Adjustment IO-Link For configuring the sensor parameters and Smart Task functions |
Adjustment |
| Adjustment | |
| IO-Link | ✔ , V1.1 |
| Emitted beam Light source LED Type of light Infrared light Number of beams 4 |
Emitted beam |
| Emitted beam | |
| Light source | LED |
| Type of light | Infrared light |
| Number of beams | 4 |
| LED key figures Normative reference EN 62471:2008-09 | IEC 62471:2006, modified LED risk group marking Free group Wave length 850 nm Average service life Average service life: 100,000 h at TU = +25 °C |
LED key figures |
| LED key figures | |
| Normative reference | EN 62471:2008-09 | IEC 62471:2006, modified |
| LED risk group marking | Free group |
| Wave length | 850 nm |
| Average service life | Average service life: 100,000 h at TU = +25 °C |
| Time specifications Initialization time 0.4 s … 2 s 5) Teach-in time 0.75 s … 50 s 5) Scan time, parallel beam 1 ms Scan time, cross beam 2 ms Repeatability, parallel beam 1 ms Repeatability, cross beam 3 ms Minimum dwell time, parallel beam 2 ms Minimum dwell time, cross beam 4 ms Max. response time, parallel beam 2.8 ms Max. response time, cross beam 5.8 ms |
Time specifications |
| Time specifications | |
| Initialization time | 0.4 s … 2 s 5) |
| Teach-in time | 0.75 s … 50 s 5) |
| Scan time, parallel beam | 1 ms |
| Scan time, cross beam | 2 ms |
| Repeatability, parallel beam | 1 ms |
| Repeatability, cross beam | 3 ms |
| Minimum dwell time, parallel beam | 2 ms |
| Minimum dwell time, cross beam | 4 ms |
| Max. response time, parallel beam | 2.8 ms |
| Max. response time, cross beam | 5.8 ms |
| Type of synchronization | Optical (2 beams) |
| IO-Link✔ , V1.1Data transmission rateCOM3 (230,4 kBaud)Cycle time2.3 msProcess data length32 ByteMaximum cable length20 m | IO-Link |
| Data transmission rate | COM3 (230,4 kBaud) |
| Cycle time | 2.3 ms |
| Process data length | 32 Byte |
| Maximum cable length | 20 m |
| Supply voltage UB | DC 18 V DC … 30 V DC 1) |
| Ripple | ≤ 1.3 Vpp |
| Power consumptionSender≤ 35.3 mA 2)Receiver≤ 41.4 mA 2) | Power consumption |
| Power consumption | |
| Sender | ≤ 35.3 mA 2) |
| Receiver | ≤ 41.4 mA 2) |
| Digital outputNumber2TypePush-pull: PNP/NPNOutput signal voltage HIGH/LOWUB-3 V/<3 VOutput load, Inductive1 HOutput load, capacitive100 nFOutput current Imax.100 mAOutput current, rest< 0.5 mA | Digital output |
| Digital output | |
| Number | 1 |
| Type | Push-pull: PNP/NPN |
| Output signal voltage HIGH/LOW | UB-3 V/<3 V |
| Output load, Inductive | 1 H |
| Output load, capacitive | 100 nF |
| Output current Imax. | 100 mA |
| Output current, rest | < 0.5 mA |
| Digital inputNumber1Input signal voltage HIGH/LOW>15 V/<5 V | Digital input |
| Digital input | |
| Input signal voltage HIGH/LOW | >15 V/<5 V |
| Protection class | III 3) |
| UL File No. | NRKH.E181493 & NRKH7.E181493 |
| Circuit protection | UV connections, reverse polarity protectedOutput Q short-circuit protectedOutputs overcurrent and short-circuit protected |
| Dimensions (W x H x D)Width11.8 mmHeight99.2 mmDepth24.1 mm | Dimensions (W x H x D) |
| Dimensions (W x H x D) | |
| Width | 11.8 mm |
| Height | 99.2 mm |
| Depth | 24.1 mm |
| Connection type | Cable with M12 male connector, 4-pin |
| Connection type DetailCable diameter3.4 mmConductor cross section0.14 mm²Length of cable150 mmCable materialPVC | Connection type Detail |
| Connection type Detail | |
| Cable diameter | 3.4 mm |
| Conductor cross section | 0.14 mm² |
| Length of cable | 150 mm |
| Cable material | PVC |
| MaterialHousingAluminumPlasticFront screenPMMA | Material |
| Material | |
| Housing | Aluminum |
| Front screen | PMMA |
| Weight | 660 g |
| Overvoltage protection (required) | 1 |
| Enclosure rating | IP65 1)IP67 |
| Ambient temperature, operation | –30 °C … +55 °C |
| Ambient temperature, storage | –30 °C … +70 °C |
| Ambient light immunity | Indirect: 50,000 lx 2) |
| Shock resistance | 10 g, 16 ms, DIN EN 60068-2-27 |
| Vibration resistance | 10-150 Hz 0.5 mm, IEC 60068-2-6 |
| Air humidity | ≤ 96 %, relative humidity (no condensation) |
| Electromagnetic compatibility (EMC) | EN 61000-6-2, EN 61000-6-4 |
| Smart Task name | Base logics |
| Logic function | DirectANDOR |
| Timer function | DeactivatedSwitch-on delayOff delayON and OFF delayImpulse (one shot) |
| Switching signalSwitching signal QL1Switching outputSwitching signal QL2Switching output, external input | Switching signal |
| Switching signal | |
| Switching signal QL1 | Switching output |
| Switching signal QL2 | Switching output, external input |
| Diagnostics functionsDevice stateHardware error, temperature warning, operating hours warningCommunication statePin short-circuit error, invalid process dataStatus of the light signalTeach error, synchronization error, quality-of-run alarmAlarm outputYes | Diagnostics functions |
| Diagnostics functions | |
| Device state | Hardware error, temperature warning, operating hours warning |
| Communication state | Pin short-circuit error, invalid process data |
| Status of the light signal | Teach error, synchronization error, quality-of-run alarm |
| Alarm output | Yes |
| EU declaration of conformity | ✔ |
| UK declaration of conformity | ✔ |
| ACMA declaration of conformity | ✔ |
| Moroccan declaration of conformity | ✔ |
| China RoHS | ✔ |
| cULus certificate | ✔ |
| IO-Link certificate | ✔ |
| Photobiological safety (IEC EN 62471) | ✔ |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | ✔ |
| ECLASS 5.0 | 27270910 |
| ECLASS 5.1.4 | 27270910 |
| ECLASS 6.0 | 27270910 |
| ECLASS 6.2 | 27270910 |
| ECLASS 7.0 | 27270910 |
| ECLASS 8.0 | 27270910 |
| ECLASS 8.1 | 27270910 |
| ECLASS 9.0 | 27270910 |
| ECLASS 10.0 | 27270910 |
| ECLASS 11.0 | 27270910 |
| ECLASS 12.0 | 27270910 |
| ETIM 5.0 | EC002549 |
Reviews
There are no reviews yet.