Description |
(CE) Conformité Européenne |
Declared to comply with all the European legislations |
Warranty |
18 months from factory discpatch |
Rated voltage, frequency |
3-phase: 380V, 50Hz/60Hz; 3-phase: 660V, 50Hz/60Hz |
Allowable range |
Voltage fluctuating range: -15%~10%; voltage tolerance: <3%; frequency: 47Hz~63Hz |
Output voltage |
Three-phase, 0V~input voltage, tolerance<5% |
Output frequency range |
VF: 0.00 – 650.00Hz; Vector: 0.00 – 200.00Hz |
Overload capacity |
150% of rated current for 60s, 180% of rated current 15s, 200% of rated current 2s |
Frequency resolution |
Digital setting: 0.01Hz; simulation setting:<2% of the maximum frequency |
Output frequency accuracy |
Analog setting: <±2% of the maximum frequency; digital setting: 0.01Hz |
Analog input AI |
2 channels AI: 0/4~20mA, 0-10V |
Analog output AO |
2 channels AO: 0/4~20mA, 0-10V |
Digital input |
5 digital inputs, NPN / PNP |
Digital output |
2 digital output, 2 relay output |
PFI / PFO |
1 channel pulse frequency input and output |
Communication |
Built-in RS485 interface with Modbus RTU, optional ModbusTCP, Profibus, Profinet |
Motor control mode |
VF, VF+PG, SVC, VC+PG |
Run command channel |
Operation panel setting, control terminal setting, communication setting |
Frequency setting channel |
Operation panel, communication, UP/DOWN regulated value, AI, PID, multi-step speed, PFI, logic |
DC braking |
Braking time: 0.0s~60.0s, braking current: 0.0%~100.0% of rated current |
Acceleration & deceleration |
Linear, S curve ACC/DEC |
Jog |
Jogging frequency range: 0.10Hz~50.00Hz |
AVR |
Automatic voltage regulation |
Automatic carrier frequency |
Automatically regulate carrier frequency according to load characteristic and environment temperature |
Droop control |
Suitable for multi-motor drive control |
Multistep speed method |
48 steps |
Multi-modes PLC |
8 sets PLC modes, max. 48 steps |
Position control |
Zero-speed position lock, position control |
Logic unit |
Comparator, logic unit, trigger, arithmetic unit, |
Others |
Tracking start, stall prevention, oscillation suppression, accurate dead zone compensation functions |
Protection |
Over-current, over-voltage, under-voltage, phase loss, output interphase short circuit, overheat, motor overload, external failure, lost connection of analog input, stall prevention, etc. |
Altitude |
With altitude below 1000m, derate >1000m |
Operating |
-10~+40℃ / 20~90%RH, without condensation water drop |
Storage temperature |
-20~+60℃ |
Vibration |
<5.9m/s2Â (0.6g) |
Degree of protection |
IP20 |
Cooling mode |
Force-air cooling |
Reviews